María Dolores Durán García

Contact description


Curriculum vitae


[email protected]


+527222453673


MECHANICAL ENEGINEERING

UNIVERSIDAD AUTONOMA DEL ESTADO DE MEXICO

Cerro de Coatepe s/n
Zip: 50110
Toluca Mexico



Efecto del proceso de combustión sobre la eficiencia total de una central térmica de vapor


Journal article


J. Jimenez-Garcia, Maria Duran-Garcia, Rigoberto Torres-Tovar, Noé Gaspar-Sánchez
Revista de Innovación Sistemática, 2019

Semantic Scholar DOI
Cite

Cite

APA   Click to copy
Jimenez-Garcia, J., Duran-Garcia, M., Torres-Tovar, R., & Gaspar-Sánchez, N. (2019). Efecto del proceso de combustión sobre la eficiencia total de una central térmica de vapor. Revista De Innovación Sistemática.


Chicago/Turabian   Click to copy
Jimenez-Garcia, J., Maria Duran-Garcia, Rigoberto Torres-Tovar, and Noé Gaspar-Sánchez. “Efecto Del Proceso De Combustión Sobre La Eficiencia Total De Una Central Térmica De Vapor.” Revista de Innovación Sistemática (2019).


MLA   Click to copy
Jimenez-Garcia, J., et al. “Efecto Del Proceso De Combustión Sobre La Eficiencia Total De Una Central Térmica De Vapor.” Revista De Innovación Sistemática, 2019.


BibTeX   Click to copy

@article{j2019a,
  title = {Efecto del proceso de combustión sobre la eficiencia total de una central térmica de vapor},
  year = {2019},
  journal = {Revista de Innovación Sistemática},
  author = {Jimenez-Garcia, J. and Duran-Garcia, Maria and Torres-Tovar, Rigoberto and Gaspar-Sánchez, Noé}
}

Abstract

In the present investigation, a simulation model of the thermal calculation of the steam generator's steam generator 350 MW, operating under a Rankine cycle with superheat and regeneration, was developed. An analysis was carried out, modifying some parameters of the combustion (air and fuel flow) and the temperatures reached by the products of the combustion at the exit of the steam generator's home were determined, using the method of successive substitutions, applied to the thermal calculation methodology, with a stopping criterion of the approximate relative error of ε_ra <1 x10-8. It was found that the temperatures reached by the combustion gases at the steam generator's outlet for the 100%, 75%, 50% and 25% regimes are: 1492.4 ° C, 1379.3 ° C, 1238.0 ° C and 980.0 ° C, respectively. Regarding the effect of air dosing on the thermal efficiency of the cycle, it is observed that it increases slightly with the increase of the dosage. Being the maximum thermal efficiency of the cycle of 35.8%