María Dolores Durán García

Contact description


Curriculum vitae


[email protected]


+527222453673


MECHANICAL ENEGINEERING

UNIVERSIDAD AUTONOMA DEL ESTADO DE MEXICO

Cerro de Coatepe s/n
Zip: 50110
Toluca Mexico



Energy and Exergy (2E) Analysis of an Optimized Solar Field of Linear Fresnel Reflectors for a Conceptual Direct Steam Generation Power Plant


Journal article


Eduardo González-Mora, M. D. Durán-García
Energies, 2021

Semantic Scholar DOI
Cite

Cite

APA   Click to copy
González-Mora, E., & Durán-García, M. D. (2021). Energy and Exergy (2E) Analysis of an Optimized Solar Field of Linear Fresnel Reflectors for a Conceptual Direct Steam Generation Power Plant. Energies.


Chicago/Turabian   Click to copy
González-Mora, Eduardo, and M. D. Durán-García. “Energy and Exergy (2E) Analysis of an Optimized Solar Field of Linear Fresnel Reflectors for a Conceptual Direct Steam Generation Power Plant.” Energies (2021).


MLA   Click to copy
González-Mora, Eduardo, and M. D. Durán-García. “Energy and Exergy (2E) Analysis of an Optimized Solar Field of Linear Fresnel Reflectors for a Conceptual Direct Steam Generation Power Plant.” Energies, 2021.


BibTeX   Click to copy

@article{eduardo2021a,
  title = {Energy and Exergy (2E) Analysis of an Optimized Solar Field of Linear Fresnel Reflectors for a Conceptual Direct Steam Generation Power Plant},
  year = {2021},
  journal = {Energies},
  author = {González-Mora, Eduardo and Durán-García, M. D.}
}

Abstract

Direct steam generation is a promising alternative to conventional heat transfer fluids for solar thermal power plants using linear concentrators because water and steam do not have thermal and chemical stability problems. The novelty of this study, an energy and exergy (2E) analysis, was that it was performed on several configurations of a conceptual direct steam generation solar power plant with optimized Fresnel reflectors in Agua Prieta, Mexico coupled with a regenerative steam Rankine power cycle to quantify their efficiency and establish a reference for future implementation of this technology in concentrated solar power plants in Mexico. The thermal model was assumed to be a 1D steady-state flow and validated against results in the literature. It was then applied directly to a case study to determine the size of the solar field. The design point was the lowest solar irradiance day, and evaluating the solar multiple with the highest solar irradiance, taking care not to oversize the solar field, as suggested for solar plants without energy storage. Comparing the performance of the optimized Fresnel field against the FRESDEMO field of Plataforma Solar de Almería, a considerable decrease in the length of the loop has been demonstrated with a low reduction in thermal efficiency.


Share

Tools
Translate to